How to Initialize the Door Operator

Prev Next

Description:

This section provides a step-by-step guide for initializing the ADC-AI-S300 automatic door operator.

Note:
Please be aware that the initialization process for the ADC-AI-S300 differs from that of Ditec door operators. To ensure proper calibration and avoid parameter misalignment, kindly follow the installation instructions for the ADC-AI-S300 model.

Operator Initialize Programing

Install the operator following the installation instructions.

  1. Ensure the door is fully closed, and that the doorway is clear of all obstacles.
  2. Turn the power ON.
    The screen will display two options, as shown in the image below:

3. Press the "ACT" button.

The door will perform two automatic self-learning cycles:

  • Cycle 1: The operator learns the door position (open/close limits).
  • Cycle 2: The operator calibrates the opening and closing speeds.

4. Upon successful completion, the screen will display: “DOOR CLOSED”, indicating the operator is ready for normal use.