Description:
This section provides a step-by-step guide for initializing the ADC-AI-S300 automatic door operator.
Note:
Please be aware that the initialization process for the ADC-AI-S300 differs from that of Ditec door operators. To ensure proper calibration and avoid parameter misalignment, kindly follow the installation instructions for the ADC-AI-S300 model.
Operator Initialize Programing
Install the operator following the installation instructions.
- Ensure the door is fully closed, and that the doorway is clear of all obstacles.
- Turn the power ON.
The screen will display two options, as shown in the image below:
3. Press the "ACT" button.
The door will perform two automatic self-learning cycles:
- Cycle 1: The operator learns the door position (open/close limits).
- Cycle 2: The operator calibrates the opening and closing speeds.
4. Upon successful completion, the screen will display: “DOOR CLOSED”, indicating the operator is ready for normal use.