--- title: "Parameter List & Descriptions" slug: "parameter-list-descriptions-v10" updated: 2025-04-29T22:30:47Z published: 2025-04-29T22:30:47Z canonical: "ametawiki.ametagroup.com/parameter-list-descriptions-v10" --- > ## Documentation Index > Fetch the complete documentation index at: https://ametawiki.ametagroup.com/llms.txt > Use this file to discover all available pages before exploring further. # Parameter List & Descriptions **Compatible model:** ADC-AI- S300 **Note:** All values and settings must comply with applicable national and provincial/state standards, including local building codes and accessibility regulations. ### Parameter table | **Index** | **Parameter** | **Description** | **Function Behavior / Effect of Adjustment** | **Value** | **Default** | | --- | --- | --- | --- | --- | --- | | 01 | Overload | Obstacle Detection Sensitivity | **Lower values increase** **sensitivity,** making the door stop or reverse more easily when resistance is detected during the opening cycle. **Higher values decrease sensitivity,** better handling **wind or pressure** but may delay obstacle detection. | 60-80 | 70 | | 02 | Act Delay | Delay between trigger and activation of ADO (10th of Second) | Shorter delays cause the door to activate more quickly after receiving a trigger. Longer delays introduce a pause before activation. Increase delay if activation button is far from the door. | 0-99 | 0 | | 03 | Backcheck Speed | Speed of the door at last 20 degrees | Controls the door speed during the final 20° of opening. The **higher** the value, the **faster** the speed. | 1-60 | 25 | | 04 | Holding Time | Time (in seconds) that the door will stay open when reaching the backcheck zone | Longer times accommodate slower users or equipment. | 0-99 | 10 | | 05 | Opening Speed | Door opening speed | Adjusts the speed at which the door opens. The **higher** the value the **faster** the speed. | 1-99 | 50 | | 06 | Closing Speed | Door closing speed | Adjusts the speed at which the door closes. The **higher** the value the **faster** the speed. | 1-99 | 30 | | 07 | Latch Speed | Door latching speed | Controls door speed during the final latching phase. The **higher** the value the **faster** the speed. | 1-99 | 10 | | 08 | Control Mode | 1 = Regular, 2 = Unlocked washroom, 3 = Access control, 4 = Locked washroom | Selects the door’s operational logic. Each mode alters how the door responds to inputs and security features. | 1-4 | 1 | | 09 | Sensor Cfg. | Safety sensor configuration selection | Specifies the **number** of connected **safety sensors**. A setting of 0 means no sensor is used. | 0-8 | 0 | | 10 | Stop Speed | The speed of the door once presence detected via sensor on swing side | Works only if **additional sensors** are being used. | 1-60 | 10 | | 11 | Power Close | Powered closing of door to positive latch (toggle) 0 = OFF, 1 = ON | Enables powered closing to fully latch the door. Useful in **high-pressure environments** or where positive latching is required. | 0-1 | 0 | | 12 | Power Cls Spd | Power closing force adjustment | Adjusts the force applied during power closing. **Higher** values provide **stronger** force to overcome resistance. | 1-35 | 20 | | 13 | Powr Cls Angle | Power Closing engage angle | Sets the door angle at which power closing begins. **Larger** angles start power closing **earlier** in the cycle. | 10-45 | 15 | | 14 | Closing Time | Countown (in seconds) to full close | Sets the countdown duration for the door to fully close. | 0-50 | 50 | | 15 | Opening Time | Countdown (in seconds) to full open | Sets the countdown duration for the door to fully open. | 0-50 | 50 | | 16 | Latch Time | Countdown (in seconds) in latch cycle | Sets the countdown duration during the latch phase. When value is 0, allows for instant locking, use 2-8 for normal door functions, lower the value the earlier the locking. | 1-8 | 2 | | 17 | Latch Angle | Latch cycle angle | Sets the angle at which the door will begin to slow before fully closing the door. Wider angles provide more control and adjustment in the final closing phase. | 1-45 | 20 | | 18 | Decel Angle | Backcheck start angle | Sets the angle at which backcheck (deceleration) begins. Higher angles trigger deceleration earlier to soften impact. | 20-110 | 80 | | 19 | Preload Time | Pull time door before opening to release pressure (10th of second) | Sets the duration the door pulls in before opening to relieve pressure. Adjust the value if there’s trouble with an electric strike. | 0-50 | 0 | | 20 | Preload Spd | Pull force of door before opening to release pressure | Adjusts the force of the preload pull before opening. Higher values increase pulling force to overcome pressure seals. | Fixed | 50 | | 21 | Wind Brake | Turn ON/OFF wind break feature 0 = OFF, 1 = ON | When enabled, the wind brake helps resist wind pressure during **door opening**, improving stability in windy environments. **Usage Note:** When manually opening the door with wind brake enabled, continue pushing the door until it is fully open. Avoid a quick push-and-release action, as this may cause the system to detect a false obstruction due to the encoder stopping abruptly. | 0-1 | 0 | | 22 | Wbrake Speed | Wind buffer force | Sets the strength of the wind buffer. Lower values apply greater resistance against wind. | 1-99 | 10 | | 23 | Wbrake Angle | Wind buffer engage angle | Defines the door angle where wind buffer engages. Adjust to tailor wind resistance response timing. | 25-110 | 60 | | 24 | Wbrake Sens | Wind buffer engage sensitivity | Adjusts the sensitivity for wind buffer activation. Higher values increase responsiveness to light wind force. | 1-99 | 20 | | 25 | Fire Al Mode | 0 = Smoke evacuation mode (door opens), 1 = NFPA80 standard (disables ADO on fire alarm) | Sets behavior in fire alarm situations. | 0-1 | 0 | | 26 | Easy Open | 0 = Heavy, 1 = Standard 15lbs, 2 = Light 5lbs | This refers to pounds of force needed to push the door manually. | 0-2 | 1 | | 27 | Quick Open | 0 = Slow ramp from full closed, 1 = Standard ramp, 2 = Quick “kick-out” for fast opening | Sets acceleration profile from closed position. | 0-2 | 1 | | 28 | Reactivate | 0 = No reactivation until fully closed, 1 = Allows reopening during closing, 2 = Touch-reverse on closing obstruction | Sets door behavior when a second open signal is received during the closing cycle. | 0-2 | 1 | | 29 | Factory Test | 0 = Normal operating state, no reset action performed, 1 & 2 = Developer use only (for testing and debugging), 3 = Perform factory reset | Set the value to 3 to clear all user parameters and reboot the system. | 0-3 | 0 |