Description
This article shows you how to default the access controller unit to factory settings.
Prerequisites
-
ASC1204C / ASC1204B - Firmware must be newer than 10/29/2015.
-
Computer with ConfigTool software installed.
Step by Step Instruction
- Launch your ConfigTool software to confirm the firmware of Access Controller.
Note: If the firmware is older than 10/29/2015, you must perform a firmware update first.
2. Locate the DIP switch on the Access Controller, and turn on DIP switch number 1, 3, 5, and 7.
-
Reboot the device by unplugging the unit from the power, or using SmartPSS software.
-
Wait until the unit completely boots back up, and then turn off DIP switch number 1, 3, 5, and 7.
-
Reboot the device again.
-
Your access controller is now set to factory default settings.
IP Address: 192.168.0.2 Username: admin Password: 123456