How to default an access controller unit?
- 11 Feb 2022
- 1 Minute to read
- PDF
How to default an access controller unit?
- Updated on 11 Feb 2022
- 1 Minute to read
- PDF
Article summary
Did you find this summary helpful?
Thank you for your feedback
Description
This article shows you how to default the access controller unit to factory settings.
Prerequisites
ASC1204C / ASC1204B - Firmware must be newer than 10/29/2015.
Computer with ConfigTool software installed.
Step by Step Instruction
- Launch your ConfigTool software to confirm the firmware of Access Controller.
Note: If the firmware is older than 10/29/2015, you must perform a firmware update first.
2. Locate the DIP switch on the Access Controller, and turn on DIP switch number 1, 3, 5, and 7.
Reboot the device by unplugging the unit from the power, or using SmartPSS software.
Wait until the unit completely boots back up, and then turn off DIP switch number 1, 3, 5, and 7.
Reboot the device again.
Your access controller is now set to factory default settings.
IP Address: 192.168.0.2 Username: admin Password: 123456